Panasonic Compressor,Copeland Semi-Hermetic Compressor,Refrigerant Gas Suppliers China Typical non-linear loads We will be focusing on the six pulse rectifier bridge. The 3 phase rectifier has a key role to play because a significant portion of the electrical energy is drawn from loads
| |||||
پیغام مدیر سایت سلام دوست من به سایت Panasonic Compressor,Copeland Semi-Hermetic Compressor,Refrigerant Gas Suppliers China خوش آمدید لطفا برای استفاده از تمامی امکانات
دانلود فایل , شرکت در انجمن و گفتگو با سایر اعضا در سایت ثبت نام کنید Typical non-linear loadsWe will be focusing on the six pulse rectifier bridge. The 3 phase rectifier has a key role to play because a significant portion of the electrical energy is drawn from loads with this type of front-end circuit. One typical application that can be mentioned is the variable speed motor drive, which has been used for years with high growth rates in almost every industrial sector. The most common six-pulse rectifier topologies are shown in Figure 1.Topology A does not include any magnetic components for smoothing the current. Topology B is operated using an upstream AC inductor Lac,usually in the form of a laminated line-reactor. Topology C has a built-in DC choke Ldc, which is often integrated in higher power motor drives. In all three topologies the grid, including the line impedance, is depicted on the left-hand side. On the right the constant power sink “P=const” represents the active power drawn from the DC/AC inverter and motor that is taken, for example, to be 20kW.
Common non-linear load topologies (six-pulsebridge rectifiers): A – without chokes; B– withAC reactor Lac; C– withDC-link chokeLdc.
Power quality and harmonics The load exerted by harmonics on the power network infrastructure has increased dramatically over the past few years. Harmonic currents are caused by non-linear loads. A non-linear load is a consumer of electricity that draws a non-sinusoidal current from the supply grid when supplied with a sinusoidal voltage. These harmonic currents flow in addition to the “active” sine-wave, generate additional losses in electrical installations, and can result in thermal over-load.
Harmonic currents flow through the system impedance, resulting in non-sinusoidal voltage drops that can compromise grid voltage quality. Sensitive loads, such as medical devices or IT infrastructure, can have their operation affected if the voltage supply is distorted.
Measures for reducing harmonics are implemented nowadays in order to resolve this issue and comply with national and international standards at every level of the network infrastructure. In this article, we will focus solely on the use of passive and active harmonic filters in low-voltage installations.
ZDDQ Related Power Quality Solutions ◆Lv Automatic Power Factor Correction ◆Hv Automatic Power Factor Correction
نمایش این کد فقط در ادامه مطلب برای قرار کد مورد نظر به ویرایش قالب مراجعه کنید
تاریخ : چهارشنبه 03 اردیبهشت 1399 نویسنده : panasoniccompressor l بازدید : 62
ارسال نظر
مطالب گذشته
» Vacuum Transformer Oil Purifier to improve the quality of oil and extend life of power equipment »» سه شنبه 07 آذر 1402
» Transformer Oil Purification Machine Performance Advantage »» سه شنبه 07 آذر 1402 » Routine inspection of high-speed nail making machine »» دوشنبه 13 شهریور 1402 » 4 reasons why the nail making machine tool damages quickly nail making machine »» دوشنبه 13 شهریور 1402 » Where is the main demand for ultra-high speed nailing machine »» دوشنبه 13 شهریور 1402 » The Global Prospects of High-Speed Nail Making Machines »» دوشنبه 13 شهریور 1402 » High Efficient Double Stage Vacuum Transformer Oil Filtration Machine »» چهارشنبه 25 مرداد 1402 » How to Choose a Suitable Oil Pump for Vacuum Oil Purifier »» چهارشنبه 25 مرداد 1402 » Filtration Process of DVTP Vacuum Transformer Oil Purifier »» چهارشنبه 25 مرداد 1402 » Transformer Oil Purification Plant in Power Equipment Maintenance »» چهارشنبه 25 مرداد 1402 | |||||
[ طراحی مجدد و ترجمه از : Ghaleb-Weblog.Ir ] [ طراح اولیه قالب ] |