|
Panasonic Compressor,Copeland Semi-Hermetic Compressor,Refrigerant Gas Suppliers China As we all know the application of frequency conversion air compressors on the market is becoming more and more extensive With the rapid development of permanent...
| |||||
|
پیغام مدیر سایت سلام دوست من به سایت Panasonic Compressor,Copeland Semi-Hermetic Compressor,Refrigerant Gas Suppliers China خوش آمدید لطفا برای استفاده از تمامی امکانات
دانلود فایل , شرکت در انجمن و گفتگو با سایر اعضا در سایت ثبت نام کنید As we all know, the application of frequency conversion air compressors on the market is becoming more and more extensive. With the rapid development of permanent magnet frequency conversion technology, the application of frequency conversion machines is still expanding. Many people may have the following questions: What is the frequency conversion of an air compressor? How does the air compressor achieve frequency conversion? How does variable frequency air compressor realize energy saving? -The meaning of air compressor frequency conversion Frequency conversion is to change the power supply frequency of the motor. Frequency conversion is abbreviated as VSD (abbreviation for Variable Speed Drive), which means variable speed drive. Air compressor frequency conversion can bring many benefits. It can reduce the starting current of the motor, reduce the impact on the user's power grid, automatically adjust the load, reduce power consumption, reduce losses, and extend the service life of the equipment. -How to achieve air compressor frequency conversion The frequency conversion technology is to rectify and filter the power frequency alternating current into a stable direct current through a rectifier circuit, and then invert it into an adjustable frequency alternating current (generally up to 400Hz) through an inverter circuit, and finally output to the variable frequency motor. The output frequency of the inverter (VSD) is proportional to the motor speed. Taking a 4-pole motor as an example, when the output frequency is 20Hz, the motor speed is 600rpm, the output frequency is 50Hz, and the motor speed is 1500rpm. When combined with an air compressor, when the gas consumption is large under normal operating conditions, the motor input frequency is high, the rotation speed is high, and the gas production is high; the noon gas consumption is small, the motor input frequency is low, the rotation speed is low, and the gas production is small. -How does variable frequency air compressor achieve energy saving Generally, users will consider the maximum production conditions when selecting the installed capacity of the air compressor. However, the actual operating conditions only reach 60%-80% of the maximum gas consumption, or even lower. The traditional fixed speed air compressor adopts loading and unloading control technology. In order not to stop when the air consumption is not large, the unloading operation is used to reduce the number of start and stop times of the motor. The motor idling does not produce compressed air in the unloaded state, and the power consumed at this time is called Unloading power is actually a waste of energy. When the air compressor adopts frequency conversion control, it is different. The frequency conversion air compressor automatically adjusts the motor speed according to the actual air demand of the production to achieve air volume adjustment. When the air volume is reduced, the air compressor automatically reduces the speed to reduce Power consumption; realizing that the gas produced by the air compressor matches the gas demand of customers from time to time, and no unloading loss is a major advantage of frequency conversion. It should be reminded here that the inverter is not energy-saving under all working conditions. As shown in the above figure, the energy-saving effect of the inverter is not so obvious when it is running at full load or close to full load. If the user's air consumption is very stable with almost no change, then it is more appropriate to choose a high-efficiency fixed-speed air compressor. Of course, this situation is relatively rare. It can be seen that the right selection has room for energy saving.
نمایش این کد فقط در ادامه مطلب برای قرار کد مورد نظر به ویرایش قالب مراجعه کنید تاریخ : جمعه 23 مهر 1400 نویسنده : panasoniccompressor l بازدید : 59
ارسال نظر
مطالب گذشته
» MTP70(4200L/H) Mobile Transformer Oil Filtering Machine Sales to Mexico »» پنجشنبه 16 بهمن 1404
» The Factors Affect Vacuum Value of Vacuum Pump Machine »» پنجشنبه 16 بهمن 1404 » VPS2000 Vacuum Pump Unit and DVTP100 transformer oil purification plant sales to Turkey »» پنجشنبه 16 بهمن 1404 » Rod Rock Bucket: The Skid Steer Attachment That Makes a Difference »» جمعه 23 آذر 1403 » Crocodile Shovel »» جمعه 23 آذر 1403 » One Unit of 6x6 High Pressure Sewage Suction Trucks Ship To Philippines »» پنجشنبه 22 آذر 1403 » One Unit of RHD 8000L Water Jet Vacuum Truck Ship to Zimbabwe »» پنجشنبه 22 آذر 1403 » One Unit Of FOTON Refrigerator Truck Ship to Cote d'Ivoire »» پنجشنبه 22 آذر 1403 » UAE Customer for Inspection of Combin Sewage Tank Truck Production »» پنجشنبه 22 آذر 1403 » The Performance of Hydraulic Oil Filter Machine for Hydraulic System Cleaning »» پنجشنبه 07 تیر 1403 | |||||
| [ طراحی مجدد و ترجمه از : Ghaleb-Weblog.Ir ] [ طراح اولیه قالب ] | |||||